Home Products Profile Contact Us Whats New
 
16 Port Plus T1 Monitoring Groomer
Hi-Z Non-Intrusive Monitoring Solution - 2U High

Product Overview

AceCom offers the MegaConnectTM 16 Port Plus - T1 (also available in E1) Monitoring Groomer is suitable for non-intrusive monitoring of upto 8, "live" T1 traffic links, bi-directionally (i.e. in both transmit and receive directions through its 16 T1 receivers) through a high impedance (Hi-Z) path. Additionally, the equipment also provides 4 output T1 ports that shall connect the aggregated time-slots which have been non-intrusively "monitored" from the 8, "live" T1 traffic links to the user's protocol analyzers, test probes, etc.

The equipment is provided with BOTH, RS232 Serial Interface for COM Port connection and as well as a TCP/IP LAN Interface (10/100BaseT) for providing equipment access through Telnet over a TCP/IP link. The user may select and use either of these ports for executing HyperTerminal text commands for configuration etc. The access for configuration and system management is provided through CLI (Command Line Interface) text commands which may be executed either from a serial (COM) Port of a PC or through the 10/100BaseT LAN Interface. The 10/100BaseT LAN Interface allows the equipment to be connected on a TCP/IP network for remote access for configuration and monitoring over LAN and TCP/IP link. The system is also supplied with an easy to use (Windows XP, Windows 7) Graphical User Interface that provides the user a complete control to prepare multiple configuration "maps" and store them, as easy to read data files. Dry contact relay alarm output is also available at rear of the system to connect the system to an external audio/visual alarm output through a dry relay contact.

The T1 Groomer is capable of non-intrusively monitoring upto 8 "live" T1 links and grooming the selected 64 Kbps time-slots to the 4 additional output T1 Ports provided in the equipment. The 16, T1 receivers of the Groomer shall connect to the 8, T1 "live traffic" links which are to be monitored, non-Intrusively. 4 additional (Normal-Z) output T1 Ports are also provided by the equipment which shall route the aggregated data of the "monitored" time-slots to the user’s test equipment, such as protocol analyzers, test probes, billing servers etc.

The T1 Groomer (T1 Monitoring DACS) is capable of monitoring a -20dBdsx (0.3Volt Pulse) T1 signal through a Hi-Z path, without in any way affecting or disturbing the "live" T1 traffic that is required to be monitored.

The equipment offers the user with complete flexibility to choose and select time-slots from each of the 8 T1 links that are being monitored, without limitation or restrictions, through the internal TSI non-blocking switch (data received by the equipment's 16 T1 receivers) and then aggregate the selected time-slots to the 4 output T1 ports that shall connect to the test probes etc.

Application Diagram

The additional solutions are offered and available for Hi-Z non-intrusive live traffic monitoring applications are:

Highlights

  • 16 T1 (or E1) ports

  • Stratum 3 clock

  • Economical

  • Compact

  • Monitoring and Grooming applications

  • Available with TCP/IP access facility for remote monitoring & access

Applications

  • 8 T1 Links (16 T1 Ports plus 4 T1 ports for connecting to monitoring equipment) T1 monitoring groomer

  • Monitoring of “Live Traffic” on T1 links which are to be monitored, non-intrusively (Hi-Z) in both transmit and receive directions.

Indications and Alarm Monitoring

  • Loss of incoming signal at any T1 Port

  • Configuration Error Alarm

  • T1 Synchronization Clock Status

  • 1 to 16 channel LED indicators to indicate the status of each T1 Monitoring Port

  • +3 Volts Power Supply

  • -48V DC present

  • Configuration Error

  • External alarm output - through a dry contact relay.

Programmable Features

  • T1 Synchronization Clock Selection (internal, incoming T1 clock, 2.048 MHz TTL External Clock)

  • Enabling or disabling T1 channels (masking) of the T1 channels that are not is use

  • Creating a cross-connect between T1s (and E1) at DS-O level (single time-slot level) using the Windows based, easy to use GUI (Graphical User Interface)

  • Telnet for remote programming

Status Monitoring

  • T1 Synchronization Clock Status

  • Status of alarms

  • Enabled / Disabled status of T1 Ports

  • Monitoring of the MegaConnectTM 16 Port Plus - T1 Monitoring Groomer, status and configuration.

Mechanical Specifications
 
Rack mounting Standard 19-Inch. DIN Rack
Height 90.00 mm.
Depth 260.00 mm.
Width 477.00 mm
Weight 4.00 kg