Home Products Profile Contact Us Whats New
 
E1, T1 and DS3 Failover / Automatic Protection Switching (APS) Solution
(E1, T1 and DS3 Failover Switch)
 
   
8 E1 Links (24 E1 Ports) Protection Switching

8E1 Links (24 E1 Ports), 1+1 Automatic Protection Switching Equipment: This equipment is to be used when the customer wants to use two different E1 links of the network to establish a 1+1 redundant path to ensure continued E1 service between two points even if one of the network E1 link fails. Example - the customer may want to use E1 Optical Fiber and an E1 Radio link and to provide an ACTIVE and a STANDBY link between a BSC and a BTS so that when the E1 Optical Fiber (ACTIVE) link goes down the STANDBY / REDUNDANT E1 Radio link automatically  gets connected to provide continued connectivity and service between the BSC and the BTS. This example is also illustrated in the product data sheets for the respective products, provided above.

Data Sheet (PDF)

   
16 E1 Links (48 E1 Ports) Protection Switching  

16 E1 Links (48 E1 Ports), 1+1 Automatic Protection Switching Equipment: This equipment is to be used when the customer wants to use two different E1 links of the network to establish a 1+1 redundant path to ensure continued E1 service between two points even if one of the network E1 link fails. Example - the customer may want to use E1 Optical Fiber and an E1 Radio link and to provide an ACTIVE and a STANDBY link between a BSC and a BTS so that when the E1 Optical Fiber (ACTIVE) link goes down the STANDBY / REDUNDANT E1 Radio link automatically  gets connected to provide continued connectivity and service between the BSC and the BTS. This example is also illustrated in the product data sheets for the respective products, provided above.

Data Sheet (PDF)

   
8 T1 Links (24 T1 Ports) Protection Switching  

8T1 Links (24 T1 Ports), 1+1 Automatic Protection Switching Equipment: This equipment is to be used when the customer wants to use two different T1 links of the network to establish a 1+1 redundant path to ensure continued T1 service between two points even if one of the network T1 link fails. Example - the customer may want to use T1 Optical Fiber and an T1 Radio link and to provide an ACTIVE and a STANDBY link between a BSC and a BTS so that when the T1 Optical Fiber (ACTIVE) link goes down the STANDBY / REDUNDANT T1 Radio link automatically  gets connected to provide continued connectivity and service between the BSC and the BTS. This example is also illustrated in the product data sheets for the respective products, provided above.

Data Sheet (PDF)

   
16 T1 Links (48 T1 Ports) Protection Switching  

16T1 Links (48 T1 Ports), 1+1 Automatic Protection Switching Equipment: This equipment is to be used when the customer wants to use two different T1 links of the network to establish a 1+1 redundant path to ensure continued T1 service between two points even if one of the network T1 link fails. Example - the customer may want to use T1 Optical Fiber and an T1 Radio link and to provide an ACTIVE and a STANDBY link between a BSC and a BTS so that when the T1 Optical Fiber (ACTIVE) link goes down the STANDBY / REDUNDANT T1 Radio link automatically  gets connected to provide continued connectivity and service between the BSC and the BTS. This example is also illustrated in the product data sheets for the respective products, provided above.

Data Sheet (PDF)

   
E1 Failover (Protection) Switch  

AceCom's E1 Fail-Over (E1 Protection) Switch (12 E1 Ports - 4 Links) allows the user to connect a single E1 line from the telephone company to an "active", as well as to a "standby" E1 terminal, such as data server / router etc. at the customer premises.

How it works: In the event of the failure of the data server / router connected to the "A / active" port of the E1 Protection (Fail-Over) Switch, it shall automatically switch and connect the E1 line from the telephone company to the data server / router on the "B / standby" port. This ensures minimum downtime - which would have otherwise   occurred due to equipment failure connected to the "A / active" port. This equipment may be used to enhance the reliability and the efficiency of the customer's data network.

Data Sheet (PDF)

   
T1 Failover (Protection)  Switch  

AceCom's T1 Fail-Over (T1 Protection) Switch (12 T1 Ports - 4 Links) allows the user to connect a single T1 line from the telephone company to an "active", as well as to a "standby" T1 terminal, such as data server / router etc. at the customer premises.

How it works: In the event of the failure of the data server / router connected to the "A / active" port of the T1 Protection (Fail-Over) Switch, it shall automatically switch and connect the T1 line from the telephone company to the data server / router on the "B / standby" port. This ensures minimum downtime - which would have otherwise   occurred due to equipment failure connected to the "A / active" port. This equipment may be used to enhance the reliability and the efficiency of the customer's data network.

Data Sheet (PDF)

   
DS3 Failover (Protection) Switch  

DS3 Fail-Over (DS3 Protection) Switch allows the user to connect a single DS3 line from the telephone company to an "active", as well as to a "standby" DS3 terminal, such as data server / router etc., at the customer premises. In the event of the failure of the data server / router connected to the "A / active" port of the DS3 Protection (Fail-Over) Switch, it shall automatically switch and connect the DS3 line from the telephone company to the data server / router on the "B / standby" port.

Data Sheet (PDF)

 

   
E3 Failover (Protection) Switch  

E3 Fail-Over (E3 Protection) Switch allows the user to connect a single E3 line from the telephone company to an "active", as well as to a "standby" E3 terminal, such as data server / router etc., at the customer premises. In the event of the failure of the data server / router connected to the "A / active" port of the E3 Protection (Fail-Over) Switch, it shall automatically switch and connect the E3 line from the telephone company to the data server / router on the "B / standby" port.

Data Sheet (PDF)

 

Products Links

Technical specifications are subject to change without notice.
All brand names and trademarks are the property of their respective owners.

.
     
 

 AceCom Networks Pte Ltd. - 2013. All rights reserved